$ EZ-EDS Version 3.9 Generated Electronic Data Sheet [File] DescText = "4050 EtherNet IP module"; CreateDate = 10-04-2010; CreateTime = 13:52:32; ModDate = 05-28-2015; ModTime = 14:21:36; Revision = 1.0; HomeURL = "www.eilersen.com"; [Device] VendCode = 471; VendName = "Eilersen Electric A/S"; ProdType = 12; ProdTypeStr = "Communications Adapter"; ProdCode = 1; MajRev = 1; MinRev = 1; ProdName = "4050"; [Device Classification] Class1 = EtherNetIP; [Assembly] Assem1 = "Configuration", "20 04 24 65 30 03", 1, 0x0000, ,, 8,; Assem2 = "Output", "20 04 24 66 30 03", 2, 0x0000, ,, 16,; Assem3 = "Input", "20 04 24 67 30 03", 26, 0x0000, ,, 16,, 16,, 32,, 16,, 32,, 16,, 32,, 16,, 32,; [Connection Manager] Connection1 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = transport type: listen-only $ 25 = transport type: input-only $ 26 = transport type: exclusive-owner $ 27 = transport type: redundant-owner $ 28-30 = reserved $ 31 = Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,,Assem2, $ O->T RPI, size, format ,,Assem3, $ T->O RPI, size, format ,, $ config #1 size, format ,Assem1, $ config #2 size, format "Exclusive Owner", $ Connection Name "", $ help string "20 04 24 65 2C 66 2C 67"; $ Path