Compression Load Cell CL (CL-Ex)
NEW hygienic (aseptic) compression load cell types CL and CL-Ex in EHEDG compliant design. These robust digital compression load cells are produced in electropolished stainless steel and hermetically sealed to IP68 for hygienic weighing installations, installations in tough environments and general process weighing. The load cells can be supplied with a hygienic base plate in AISI316. The compression load cell type CL-Ex can be used in ATEX (Ex) and IECEx applications (Zone 1, 2, 21 and 22).








Special Features
|
|
Documentation
Dimensions (mm)

Specifications
Parameter | Unit | 0.10% | 0.05% | 0.025% |
Rated capacity (Emax) | kg | 50, 100, 150, 250, 500, 1000, 1500, 2000, 3000, 4000, 5000 | ||
Safe overload limit | % of Emax | 200 to 500 | ||
Safe sideload limit | % of Emax | 300 to 1000 | ||
Minimum dead load | % of Emax | 0 | ||
Combined accuracy | % of Emax | 0.100 | 0.050 | 0.025 |
Repeatability | % of Emax | 0.030 | 0.025 | 0.020 |
Hysteresis | % of Emax | 0.055 | 0.040 | 0.020 |
Creep 30 min. | % of Emax | 0.060 | 0.040 | 0.040 |
Temperature effect on zero | % /10°C | 0.060 | 0.055 | 0.055 |
Temperature effect on sensitivity | % /10°C | 0.060 | 0.055 | 0.055 |
Compensated temperature range | °C | -10 to 50 | ||
Operating temperature range | °C | -50 to 70 (100*) | ||
Deflection at Emax | mm | max 0.10 | ||
Measuring rate | Hz | 500 | ||
Supply | Vdc | 24Vdc ±5% | ||
Internal resolution | Bit | 24 | ||
Material | Stainless Steel 17-4 PH and AISI 316 | |||
Protection | IP68 | |||
Cable | 6 meter standard coaxial RG-58 (Ø6mm) with BNC connector | |||
Maximum cable length | m | 100 | ||
Weight | kg | 2.0 | ||
Output options | EtherNet/IP, PROFINET, EtherCAT, Profibus DP, Modbus TCP/IP, DeviceNet, RS485, 4-20mA, 0-10Vdc |
* with teflon cable
Applications
- Tank weighing
- Process weighing
- Big-bag equipment
- Filling and dosing
- Offshore
- Level measurement
- Platform scales
- Hopper scales
- Heavy duty applications
- Belt scales
Options
- ATEX and IECEx (Zone 1, 2, 21, 22) version type CL-Ex
- ATEX II 2G Ex ia IIC T6 Gb / ATEX II 2D Ex ia IIIC T85°C Db
- Standard and hygienic base plate available
- Load cell cable length 10, 20, 50 or 100 meters
- Mud resistant and Halogen free cables for offshore installation
- Special PE load cell cable available for freezing low temperature (can be used down to -50 degrees Celsius)
- Special Teflon load cell cable available for very high temperature (can be used up to 100 degrees Celsius)
Related Products
Compression Load Cell CM (CM-Ex) 125
NEW hygienic (aseptic) compression load cell types CM and CM-Ex with 125mm diameter in EHEDG compliant design. These robust digital compression load cells are available in capacities up to 20 tons and produced in…Compression Load Cell CM (CM-Ex) 150
NEW hygienic (aseptic) compression load cell types CM and CM-Ex with 150mm diameter in EHEDG compliant design. These robust digital compression load cells are available in capacities up to 50 tons and produced in…ATEX PROFINET Interface Module 4X70A
ATEX and IECEx certified (zone 1, 2, 21, 22) PROFINET interface module for directly interfacing up to 4 digital ATEX / IECEx load cells via PROFINET. The interface module type 4X70A can also be used in non-ATEX…Beam Load Cell BL (BL-Ex)
Robust digital beam load cell in a hygienic (aseptic) design for dynamic weighing, process weighing, filling, packaging and general weighing in food, pharma and life science applications. The new hygienic EHEDG compliant…Digital LCD Weighing Indicator 5024G
Fully digital OIML certified weighing indicator type 5024G with alibi memory and software for standard weighing applications. Digital signal processor for displaying and processing data from the Eilersen range of digital load…Plug-and-play interface modules
Accurate and reliable communication to PLC's, SCADA, and control systems
Our interface modules support all communication protocols on the market, including EtherNet IP, PROFINET, and EtherCat, and all our interface modules have direct fieldbus interfaces and analogue I/O.
Digital technology ensures high accuracy and resolution
When you combine Eilersen interface modules with Eilersen digital load cells, your measuring chain is purely digital. There is no loss of signal as there is no A/D conversion. As a result, you get the most accurate measurement and the highest resolution possible.
Standard or customized firmware
Our wide range of direct fieldbus interfaces make our interface modules easy to connect to your existing PLC’s and control systems. Besides standard firmware, all products can be delivered with customized firmware to suit your needs.
Monitor up to 16 load cells from one interface module
The integrated monitoring provides data of loads on the individual digital load cells and even offer integrated diagnostics. Even though Eilersen load cells don’t require regular maintenance, this feature makes troubleshooting fast and easy should the need for maintenance occur.
Suitable for all environments
No matter your industry or environment, we have interface modules and solutions to suit your needs. Eilersen interface modules can be delivered in ATEX and IECEx certified versions that ensure safety and reliability in demanding conditions.

Request a Quote
Looking for a tailored weighing solution? Fill out the form below, and our experts will provide you with a customized quote based on your specific needs. Whether you're in food, pharma, or another industry, we'll help you find the perfect solution.
Get started today
Complete the form, and we’ll get back to you promptly with a competitive quote and expert guidance to fit your requirements.